The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports....
Search Results "Transfer Support"
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations...
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
5.1.4 Transfer Surface Height Measurement for M301 and M302 The Committee recommends capturing the transfer surface height at the highest point of the seat in an uncompressed state, inclusive...
-
1f
Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and to aid in transfer from a wheelchair to the folding shower seat...
-
(4) Adjustability: Method of Measurement
used in the seated position, be taken from the floor to the top of the transfer surface (proposed M301.2.1 and M302.2.1, respectively)....
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
Therefore, transfer surfaces that are adjustable to a 25 inches maximum during patient transfer accommodate most patients who use mobility devices....
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
For some, independent transfers are only possible when there is minimal or no change in vertical height between the seat of the mobility device and the transfer surface....
-
Hologic, Inc.
The patient is lying in the prone position on a cushioned table, with her breast positioned beneath the patient support surface while the physician works underneath the table....
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum....
-
A4.16.4 Grab Bars
A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
A4.16.4 GRAB BARS
A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs....
- Autoadapt Turny Evo
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings....
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings....
-
§1193.33 Information, documentation, and training.
[See subsections ...]
-
Section 1193.33 Information, Documentation, and Training (Advisory Guidance)
Section 1193.33 Information, Documentation, and Training
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches. This is consistent with the 2004 ADA and ABA...
-
206.2.9.2 Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices
206.2.9.2 Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices....
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....