Yes, where transfer access is provided on a composite play structure elevated play components such as a crawl tube are permitted to connect to other play components....
Search Results "Transfer Shower"
Commonly Searched Documents
-
8. Can an elevated crawl tube be used to connect to a play component required to be accessible? Can that crawl tube also be considered an accessible play component?
-
Types of Alternative Designs
Shower: Roll-in showers were used, but sidewalls were minimized to permit access by a caregiver from outside the fixture....
- Figure 1008.3.2 Transfer Steps – Drawing from the U.S. Access Board
-
RECOMMENDED CHANGE
RECOMMENDED CHANGE Revise the Section 5.4.11 recommendation as follows: The Committee recommends transfer supports and connections contain the strength to resist vertical forces of...
-
5.1 Transfer Surface Height Recommendations
5.1 Transfer Surface Height Recommendations Description: The transfer height is set above the finished floor surface to permit transfers form mobility devices onto the transfer surface...
- Symmons Duro® Tub Shower System 3S603-H321-V
-
Outdoor showers on a swimming pool deck, Title III entities
I have a new swimming pool project with two outdoor rinsing showers on the pool deck (owner is a Title III entity)....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
- Speakman Versatile Handheld Shower System SM-5040
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height...
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The side...
-
11B-610.3.1 Rectangular seats
11B-610.3.1 Rectangular seats. The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height...
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]...
-
4.26.1* GENERAL
All handrails, grab bars, and tub and shower seats required to be accessible by 4.1, 4.8, or 4.9 shall comply with 4.26....
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement....
-
4.26.1* General
All handrails, grab bars, and tub and shower seats required to be accessible by 4.1, 4.8, 4.9, 4.16, 4.17, 4.20 or 4.21 shall comply with 4.26....