With its telescoping function and full break-out capability, the door package can provide up to 80 inches of clear opening width in a full 12-foot system....
Search Results "Lavatory Clear Floor Space"
- Horton Automatics Profiler® Smoke-Rated Telescoping ICU/CCU Sliding Door
- Inclusion Solutions Freestanding Totem Pocket Display
- Panda S.81 All Aluminum Multi-Slide Door System
-
6.1 Deliberative Process
In an effort to be consistent and establish a clear minimum, the Committee focused its subsequent deliberations on a single endpoint for the transfer surface low height recommendation....
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
§8.3 Accessible route
Accessible route means a continuous unobstructed path connecting accessible elements and spaces in a building or facility that complies with the space and reach requirements of applicable...
-
4.34.2(15)
(15) The following spaces shall be accessible and shall be on an accessible route: (a) The living area. (b) The dining area....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
On-Site Readers
Specific skills are needed to be an on-site reader: ability to read material well, a good clear voice, and, ideally, knowledge of the language and vocabulary used in the documents....
-
Escalators
Escalators must have a clear width of at least 32” and meet specific provisions in the ASME A17.1 Safety Code for Elevators and Escalators....
-
§382.67(a)
(a) As a carrier, you must ensure that there is priority space (i.e., a closet, or a row of seats where a wheelchair may be strapped using a strap kit that complies with applicable Federal...
-
1003.2.13 Accessible means of egress
Accessible spaces shall be provided with not less than one accessible means of egress....
-
R204.2 Sidewalks
The pedestrian access route shall connect to accessible elements, spaces, and facilities required by this document and to accessible routes required by section 206.2.1 of appendix B to 36...
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point not less than 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
1.9.1.2
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...