The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....
Search Results "Lavatory Clear Floor Space"
-
Seat Height
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
G. Compartment Size
If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use wheelchairs...
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
§ 38.37(b)
(b) Controls required by paragraph (a) of this section shall be mounted no higher than 48 inches and no lower than 15 inches above the floor, shall be operable with one hand and shall not...
-
11B-502.6 Identification
NOTES 11B-502.6 Identification Amends current regulations to require the International Symbol of Accessibility at accessible parking spaces...
-
B5
Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions?...
-
1017.6 Openings
This section requires openings in the surface of trails, passing spaces, and resting intervals such as spaces between the boards in a boardwalk to not allow passage of a sphere more than...
-
ESSENTIAL FEATURES
Those elements and spaces that make a building or facility usable by, or serve the needs of, its occupants or users....
-
Baby Changing Tables
Certain elements are permitted to overlap space at water closets, such as grab bars, paper dispensers, and coat hooks (604.3.2)....
-
Application [§201]
Requirements in the standards apply to both exterior and interior spaces and elements provided on a site, usually without distinction....
-
Are there any situations in which an animal would not be permitted to accompany its user on the flight?
The only situation in which the rule contemplates that a service animal would not be permitted to accompany its user at his or her seat is where the animal blocks a space that, per FAA or...
-
11B-208.3.2 Residential facilities
residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Chapter 11A, Division IV, parking spaces...
-
11B-208.3.2 Residential facilities
residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Chapter 11A, Division IV, parking spaces...
-
11B-208.3.2 Residential facilities
dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Sections 11B-809.6 through 11B-809.12 parking spaces...
-
Protruding Objects [1016.9]
Objects that protrude into ORARs, passing spaces, and resting intervals can pose hazards to people who are blind or have low vision....
-
1004.2.1 Exit or exit access doorways required
Two exits or exit access doorways from any space shall be provided where one of the following conditions exists: The occupant load of the space exceeds the values in Table 1004.2.1...
-
Error/Omission: The built-up curb ramp projects into the access aisle.
The accessible parking space and access aisle is not level in all directions....
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....