(a) The provisions of 9.5.3 and 9.1.5 shall apply to sleeping rooms and beds....
Search Results "Sleeping Compartment"
Commonly Searched Documents
-
9.5.2(1)(a)
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Requirement: 9.4 Other Sleeping Rooms and Suites....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
11B-222.2 Coat hooks and shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.5....
-
11B-222.2 Coat hooks and shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.5....
-
11B-222.2 Coat hooks and shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.5....
-
213, 603, 604, and 608 Toilet and Bathing Facilities, Rooms, and Compartments
[See subsections ...]
- Bradley Standard Series Napkin Disposal
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
222 Dressing, Fitting, and Locker Rooms
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds. ...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds....
-
HOUSING
A building, facility, or portion thereof, excluding inpatient health care facilities, that contains one or more dwelling units or sleeping accommodations....
-
Chapter 6: Plumbing Elements and Facilities
Chapter 6 provides criteria for drinking fountains (602), toilet and bathing rooms (603), water closets and toilet compartments (604), urinals (605), lavatories and sinks (606), bathtubs...
-
Coat Hooks and Shelves
Section 213.3.7 addresses coat hooks and shelves provided in accessible toilet rooms, toilet compartments, and bathing facilities and references corresponding technical criteria for such...
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
-
Dispersion: ADA Standard Section 224.5
Section 224.5 covers scoping requirements in the current ADA Standards for dispersion of transient lodging guest rooms.
-
11B-224.5 Dispersion
For the purposes of the application of this section, the term "sleeping room" is intended to be used interchangeably with the term "guest room" as it is used in the transient lodging standards...
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
For the purposes of the application of this section, the term "sleeping room" is intended to be used interchangeably with the term "guest room" as it is used in the transient lodging standards...
-
9.2.2 Minimum Requirements
An accessible unit, sleeping room or suite shall be on an accessible route complying with 4.3 and have the following accessible elements and spaces....