In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
Search Results "Hoistway Door"
Commonly Searched Documents
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
-
D4. Door Clearance
On the pull side of the door, is there at least 18 inches clearance provided to the side of the latch if the door is not automatic or power-operated?...
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Door Arm Pivot Variations Video
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Adjusting Spring Door Tension Video
- Access Board: Automatic Door Controls
-
(4) Doors to public and common use areas
The final Guidelines continued to provide that on accessible routes in public and common use areas, and for primary entry doors to covered units, doors that comply with ANSI 4.13 meet the...
-
2.2 Entrances
Can the accessible entrance be used independently, or is the door heavy or usually locked? Is the entrance door at least 32 inches wide?...
-
M3
M3. Is the hardware (e.g., lever, pull, etc.) usable with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.13.9] Yes No If No,...
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
- Boost Your Business - Chapter 6 - Doors
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close....
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close....
-
H24
Unless the wide stall is located at the end of a row of toilet stalls, does the door to this wider stall open out? [ADA Standards § 4.17.3] Yes No...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
- FlexCounter™ - Window Door Combination
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
- LaCantina Doors - Contemporary Clad Industrial
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]