Additionally, the final Guidelines provide that at the primary entry doors to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such...
Search Results "Hoistway Door"
Commonly Searched Documents
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
-
Toilet Compartment Access
If the door and access were from the opposite side, although not as accessible I believe it is also §404 compliant because a self-closing door is not the same as a door with a closer? ...
- Doug Mockett & Company SDH1 Sliding Door Hardware
-
4.1.3(7)(c)
(c) Each door that is an element of an accessible route shall comply with 4.13....
-
4.1.3(7)(d)
(d) Each door required by 4.3.10, Egress, shall comply with 4.13....
-
Minimum Clear Opening
The issue of minimum clear opening for doors was one of the most widely commented-upon design features of the guidelines....
-
(3) Doors within individual dwelling units
The final Guidelines recommend that doors intended for user passage within individual dwelling units have a clear opening of at least 32 inches nominal width when the door is open 90 degrees...
-
4.10.4 Hall Lanterns
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
11B-604.8.1.1.1 Maneuvering space with in-swinging door....
- Adjusting the Hager Companies 5100 Door Closer
-
4.1.3(7)(b)
(b) Within a building or facility, at least one door at each accessible space shall comply with 4.13....
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...
-
Car Dimensions: ADA Standard Section 407.4.1
Section 407.4.1 covers the current ADA Standards for elevator car dimensions.
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
6.3(5)
(5) Each bedroom shall have a door that complies with 4.13....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
- ADAEZ Pro Plus Automatic Door Opener Locating Operator Mounting Bracket Video
- SafeZone: Cast Iron Door Closer Animation
- How to Install Allegion Falcon SC71 Door Closer
-
Corbin Russwin Inc. Cast Iron Door Closer
Requires the Registered User plan or above. Login!