TS5000 series is a grade 2 rim device and UL listed as fire hardware. ...
Search Results "Door Hardware"
- TownSteel TS8000 Grade 2 Fire Rim Device
-
Re: 404.2.6 Doors in Series and Gates in Series
My understanding is that it was written to keep wheelchair users from having to fight two doors at once. ...
- Hager Companies Round Wrought Door Pull 4
- Hager Companies Round Wrought Door Pull 3
-
Door Protective and Reopening Device [4.10.6]
Door reopening devices must be able to detect obstructions without contact; otherwise, they can disrupt the balance of people using crutches or canes....
-
Communication Access at Doors [§806.3.2, §809.5.5]
Communication Access at Doors [§806.3.2, §806.3.2] ETA Editor's Note This section title contains a typo, as it duplicates section number "806.3.2."...
- TownSteel ED1100 Grade 1 Panic Rim Device
- TownSteel ED1400 Grade 1 Mortise Panic Device
- Architectural Builders Hardware Mfg., Inc. 6830 Series Time Out/Reverse Low Profile Hospital Latch
- Sargent FM7100 Multi-Point Auto Deadlocking Door System
- Hager Companies Rectangular Wrought Door Pull 2
- Sargent 7800 Mortise Lock with Push/Pull Trim Hardware
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
-
Guestroom Doors
Guestroom Doors Common Problem: Doors and doorways into and within all guestrooms and suites, including bathroom doors and doorways, do not allow 32 inches of clear opening width....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
(1)(e)
Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
-
Closers
Closers Automated door closing is addressed by the ANSI/BHMA standards....
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
- TownSteel ED1400F Grade 1 Mortise Fire Device
- TownSteel ED5500F Grade 1 Fire Rim Device
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...