The water closet shall be located with a wall or partition to the rear and to one side....
Search Results "Back Wall"
-
11B-604.9.1 Location
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-1009.2.4 Seat
The seat shall be rigid and shall have a back support that is at least 12 inches (305 mm) tall....
-
11B-1009.2.4 Seat
The seat shall be rigid and shall have a back support that is at least 12 inches (305 mm) tall....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. [ECTCR UFAS 4.34.5.2(3)] EXCEPTIONS: 1....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1....
-
1134A.7, Item 1
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or...
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
A4.34.6.8 REFRIGERATOR/FREEZERS
Locating refrigerators so that their doors can swing back 180 degrees is more convenient for wheelchair users....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
Grab Bars
Grab bars are required on one side wall and the rear wall....
-
H1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch?...
-
4.30.6 Mounting Location and Height
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
Switching Between Voice and TTY Modes
All call takers must have the capability to switch back and forth easily from TTY mode to voice mode during the same call....
-
4. ABSOLUTE DIMENSIONS
For instance, consider the requirement that water closets (toilets) be an absolute 18" from the adjacent wall to the centerline....
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
Standard Stall
Recommendation: Ceiling-mounted partitions are a good idea because toe clearance is not interrupted by vertical supports [sic] Because floor-mounted toilets commonly project further from the back...