Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this chapter....
Search Results "Slope"
-
11B-405.7 Landings
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this chapter....
-
11B-233.3.1.2.6.2 Test number one, individual building test
The slopes of the undisturbed site measured in a straight line between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15,240 mm) of the planned entrance...
-
11B-233.3.1.2.6.2 Test number one, individual building test
The slopes of the undisturbed site measured in a straight line between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15,240 mm) of the planned entrance...
-
Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
Gangway
A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this document....
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
GANGWAY
[DSA-AC] A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this code....
-
GANGWAY
[DSA-AC] A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this code....
-
Turning Space: ADA Standard Section 1010.1
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
Start of Play: ADA Standard Section 1007.3.1
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
2. Electronic (Digital) Level
Even experts can misjudge how steep a running slope or cross slope is if they do not use a level....
-
11B-406.3.2 Turning space
The slope of the turning space in all directions shall be 1:48 maximum....
-
11B-406.3.2 Turning space
The slope of the turning space in all directions shall be 1:48 maximum....
-
M303.3.3 Ramped (Section-by-Section Analysis)
, cross slope, clear width, edge protection, and handrails....
-
11B-406.5.6 Grade breaks
Surface slopes that meet at grade breaks shall be flush....
-
11B-406.5.6 Grade breaks
Surface slopes that meet at grade breaks shall be flush....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....