Exception: Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or...
Search Results "Residential Dwelling Unit for Sale"
-
11B-224.7 Housing at a place of education
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.
-
11B-809.7 Accessible routes
The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and exterior decks and balconies....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
1150A.1 General
Except as provided for in Section 1102A.3.1, the provisions of this section do not apply to multistory dwelling units in nonelevator buildings....
-
1150A.1 General
Except as provided for in Section 1102A.3.1, the provisions of this section do not apply to multistory dwelling units in non-elevator buildings....
-
21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
Under Requirement 4, there must be an accessible route into and through the dwelling unit. This would preclude a split level foyer, unless a properly sloped ramp can be provided....
-
F233.3.3 Alterations
EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
- Verifone MX 915 Point of Sale Machine with Credit Card Reader
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914...
-
§100.205(c)(3)(i)
(i) An accessible route into and through the covered dwelling unit;...
-
7(2)(a)(iii)
(iii) If the shower stall is the only bathing facility provided in the covered dwelling unit, or on the accessible level of a covered multistory unit, the shower stall measures at least...
-
233.3.5 Alterations, F233.3.4 Alterations, F233.4.5 Alterations
In addition, at least 2 percent of the residential dwelling units shall comply with 809.3. 233.3.5.2 Alterations to Individual Residential Dwelling Units....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
233 Residential Facilities
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted....
-
11B-224.8 Social service center establishments
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units subject to this...
-
11B-809.8.2 Door opening force
Doors shall comply with Section 11B-404.2.9. Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
Costs of Adaptation
A few commenters requested clarification on who incurs the cost of making a unit adaptable for a disabled tenant. Response....