The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1 _|Braille Dimensions|_....
Search Results "Handrail Diameter"
Commonly Searched Documents
- 
    
  
  11B-407.4.7.2 Keypads
  
 - 
    
  
  11B-707.9.1.1 Tactilely discernible numerical keypad
  
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
 - 
    
  
  1991 Standards v. 2010 Standards
  
The 1991 Standards, at sections 4.8.5, 4.9.4, and 4.26, and the 2010 Standards, at section 505, contain technical requirements for handrails....
 - 
    
  
  1607.8 Loads on handrails, guards, grab bars shower seats, dressing room bench seats and seats
  
[See subsections ...]
 - 
    
  
  M303.3.3 Ramped (Section-by-Section Analysis)
  
wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with technical requirements for running slope, cross slope, clear width, edge protection, and handrails...
 - 
    
  
  Access to Performing Areas [4.33.5]
  
While handrails are not required on ramps adjacent to assembly seating, locating aisles (including those that are stepped) along walls will permit handrails on one side for the benefit of...
 - 
    
  
  R411 International Symbol of Accessibility (Section-by-Section Analysis)
  
R411 International Symbol of Accessibility (Section-by-Section Analysis) The technical requirements ramps, stairways, handrails, visual characters on signs, and the International Symbol...
 - 
    
  
  Library
  
Offset pivot hinge on door to library Large print books in the library Handrails at two height Evaporative cooler to save the energy used by air conditioners...
 - 
    
  
  Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
  
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
 - 
    
  
  Pushbutton-integrated APS
  
All include a pushbutton that is at least 50 mm (2 inches) in diameter, audible and vibrotactile WALK indications, a pushbutton locator tone, a tactile arrow, and automatic volume adjustment...
 - 
    
  
  5.3.2.1 Size
  
The turning space shall be at least 60 inches (1,525 millimeters) in diameter or T-shaped with a minimum 60- by 36-inch (1,525 by 915 millimeter) arm and a minimum 36-inch (915 millimeter...
 - 
    
  
  2. a. iv. Path-of-Travel (wheelchair) space allowances
  
If a 180° turn is needed to exit an area, then a 60” diameter turning space or a 36” wide "T" is needed (see Figure 11)....
 - 
    
  
  5.3.2.1 Size
  
The turning space shall be at least 60 inches (1,525 millimeters) in diameter or T-shaped with a minimum 60- by 36-inch (1,525 by 915 millimeter) arm and a minimum 36-inch (915 millimeter...
 - 
    
  
  11B-405.9.2 Curb or barrier
  
A curb, 2 inches (51 mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102...
 - 
    
  
  11B-405.9.2 Curb or barrier
  
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
 - 
    
  
  1003 Recreational Boating Facilities
  
Requirements for accessible routes and ramps are applied to gangways, but exceptions to criteria for maximum rise and slope, handrail extensions, and level landings are provided....
 - 
    
  
  Steps
  
Most building codes require handrails for a certain change in level or number of steps....
 - 
    
  
  Openings [1018.6]
  
Openings in the surface of beach access routes and resting intervals must be small enough so that a sphere more than one-half inch in diameter cannot pass through....
 - 
    
  
  Conventional Strollers
  
Conventional Strollers These devices typically have four wheels or four pairs of wheels; the wheels are generally small, about 150 mm (6 inches) in diameter....
 - 
    
  
  Attachment I: Program Access in Existing Facilities
  
Attachment I: Program Access in Existing Facilities
 - AquaTrek2 ADA Wading Pool Ramp
 - 
    
  
  Clear Width [4.8.3]
  
The minimum dear width for ramps of 36 inches is measured between the leading edge of handrails. A maximum clear width is not specified....
 - 
    
  
  Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
  
The IBC contains requirements for exit stairway enclosures that address fire-resistance and smoke protection, stairways and handrails, signs, and other features....
 - 
    
  
  Question: Alteration vs. Maintenance for Stairs in Pre-ADA Building
  
However, some of the existing wooden handrails are rotted and need to be replaced....