A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....
Search Results "Floor Slope"
Commonly Searched Documents
- 
    
  
  4.18.3 CLEAR FLOOR SPACE
  
 - 
    
  
  1004.1 Clear Floor Space
  
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
 - 
    
  
  1004.1 Clear Floor Space
  
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
 - 
    
  
  611.2 Clear Floor Space
  
611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided....
 - 
    
  
  11B-704.2.1 Clear floor or ground space
  
11B-704.2.1 Clear floor or ground space. A clear floor or ground space complying with Section 11B-305 shall be provided....
 - 
    
  
  Performance and the Surface Deficiency Score
  
A digital level and tape measure were used to identify instances along the accessible routes and at clear floor spaces where the surface running slope exceeded 1:16 (6.25%); the cross slope...
 - 
    
  
  11B-704.2.1 Clear floor or ground space
  
A clear floor or ground space complying with Section 11B-305 shall be provided. The clear floor or ground space shall not be obstructed by bases, enclosures, or seats....
 - 
    
  
  11B-704.2.1 Clear floor or ground space
  
A clear floor or ground space complying with Section 11B-305 shall be provided. The clear floor or ground space shall not be obstructed by bases, enclosures, or seats....
 - 
    
  
  Inpro Corporation JointMaster® 103 VCT Expansion Joint Systems  Floor to Floor
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  Inpro Corporation JointMaster® 101 Floor Expansion Joint Covers Floor to Wall
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  602.2 Clear Floor Space
  
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
 - 
    
  
  R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control
  
Where pedestrian access routes are contained within pedestrian street crossings without yield or stop control, the cross slope of the pedestrian access route shall be 5 percent maximum....
 - 
    
  
  General: ADA Standard Section 302.1
  
Section 302.1 of the ADA Standards covers information in the current ADA Standards for floor or ground surfaces.
 - 
    
  
  Clear Floor Space [4.16.2]
  
Clear Floor Space [4.16.2] ADAAG (Figure 28) specifies the amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor...
 - 
    
  
  602.2 Clear Floor Space
  
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
 - 
    
  
  611.2 Clear Floor Space
  
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
 - 
    
  
  611.2 Clear Floor Space
  
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
 - 
    
  
  Clear Floor Space [§309.2]
  
Clear Floor Space [§309.2] Clear floor space for forward approaches must extend up to or, if knee or toe space is provided, below operable parts....
 - 
    
  
  809.2.1.2 Floor Surfaces
  
809.2.1.2 Floor Surfaces This section specifies that carpet not be provided on floor surfaces in emergency transportable housing units with mobility features....
 - 
    
  
  5.8.1.2.1 Ramped Entry Slope Recommendations
  
5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the slope...
 - 
    
  
  11B-809.10.8.2 Floor space
  
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
 - 
    
  
  408.4.2 Floor Surfaces
  
408.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303....
 - 
    
  
  Inpro Corporation JointMaster® 806 Series Floor Expansion Joint Covers Floor to Wall
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  Are curved or circular ramps allowed?
  
Ramps without level landings at changes in direction typically will not meet the Standards due to resulting compound slopes....