A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
Search Results "Floor Slope"
Commonly Searched Documents
- 
    
  
  11B-904.4.1 Parallel approach
  
 - 
    
  
  1133A.2 Clear floor space
  
1133A.2 Clear floor space. Clear floor space at kitchens shall comply with the following:...
 - 
    
  
  Clear Floor Space: Minimum Clear Floor Space Required - Manual, Power & Scooter
  
Clear floor area dimensions are used for determining the size of spaces designated for wheeled mobility users (such as on buses, in movie theaters, sports stadiums)....
 - Inpro Corporation JointMaster® 806 Series Floor Expansion Joint Covers
 - 
    
  
  811.2 Clear Floor or Ground Space
  
811.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided....
 - 
    
  
  11B-602.2 Clear floor space
  
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
 - 
    
  
  11B-602.2 Clear floor space
  
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
 - 
    
  
  4.25.2 Clear Floor Space
  
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 that allows either a forward or parallel approach by a person using a wheelchair shall be provided at...
 - 
    
  
  4.25.2 CLEAR FLOOR SPACE
  
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 that allows either a forward or parallel approach by a person using a wheelchair shall be provided at...
 - 
    
  
  Visible Indicators: ADA Standard Section 407.4.7.1.4
  
Section 407.4.7.1.4 covers the current ADA Standards for visible indicators on elevator car control buttons.
 - 
    
  
  11B-407.4.7.1.4 Visible indicators
  
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
 - 
    
  
  Wading pools. (Section-by-Section Analysis)
  
Almost all commenters felt that during alterations a sloped entry should be provided unless it was technically infeasible to do so....
 - 
    
  
  1133A.2 Clear floor space
  
Clear floor space at kitchens shall comply with the following: A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in...
 - 
    
  
  Beds: ADA Standard Section 807.2.3
  
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
 - 
    
  
  11B-611.2 Clear Floor Space
  
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
 - 
    
  
  11B-611.2 Clear Floor Space
  
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
 - Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
 - 
    
  
  11B-807.2.3 Beds
  
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
 - 
    
  
  Parallel Approach: ADA Standard Section 904.4.1
  
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
 - Inpro Corporation JointMaster® 300 Series Recessed Mount Floor Expansion Joint Covers
 - 
    
  
  11B-608.2.2.1 Clearance
  
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
 - 
    
  
  Accessibility
  
Accessibility: When ceramic tile is used as the flooring surface, design professionals should consider the following, based on ANSI A108.01 and A108.02, where accessibility is a primary...
 - 
    
  
  4.16.2 CLEAR FLOOR SPACE
  
Clear floor space for water closets not in stalls shall comply with Fig. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach....
 - 
    
  
  Do the surface requirements, including those for maximum slope (1:48), apply to all portions of a parking lot?
  
No, the surface criteria apply only to accessible parking spaces, access aisles, and accessible routes, including those serving other elements or spaces besides parking spaces....