Mia Schaikewitz, from the Push Girls, helps architects understand the proper mounting heights and reach ranges for commercial restrooms fixtures for ADA compliance. Please go to...
Search Results "Clearance"
Commonly Searched Documents
- Bobrick Accessibility Video -- Mounting Height and Reach Ranges
-
T303 Handrails, Stanchions, and Handholds
The technical requirements for handrails, stanchions, and handholds include specifications on edges, cross sections, and clearances (i.e., space between gripping surface and adjacent surface...
- Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms – Drawing from the U.S. Access Board
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
1016.9 Protruding Objects
However, entities should maintain the vertical clearance along outdoor recreation access routes, resting intervals, and passing spaces free from tree branches for 80 inches high minimum...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. ...
-
Forward Approach
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1....
- Guldmann Excellent Ramp System
-
1133A.2, Item 2
2. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other...
-
1133A.2 Clear floor space
1133A.2 Clear floor space. Clear floor space at kitchens shall comply with the following:
-
Question 10
YES/NO 10. Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door...
-
1k
k. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
C. Doors
C. Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into...
-
J6
J6. Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a...
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement...
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
4.20.2 Floor Space
Clear floor space in front of bathtubs shall be as shown in Fig. 33.
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
4.20.2 FLOOR SPACE
Clear floor space in front of bathtubs shall be as shown in Fig. 33.