The restroom vestibule door does not have the required minimum of 18" maneuvering clearance on the latch side of the door. See Standards § 4.13.6. l....
Search Results "Clearance"
Commonly Searched Documents
-
Restrooms Main Lobby
-
§ 38.155(a)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
Opening Doors From a Wheelchair Video
Requires the Registered User plan or above. Login!
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
806.2.3 Sleeping Areas
806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm)...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm)...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
609.3 Spacing
609.3 Spacing. The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches...
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and...
-
Doors [4.35.3]
Doors [4.35.3] The size of rooms is further determined by the location and swing of doors. Doors cannot swing into the turning space (as allowed in toilet and bathrooms because...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm)...
-
§ 38.95(d) Mobility aid seating location
(d) Mobility aid seating location. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches. Such...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
2010 ADA Standards - Plan Review Tool - Doors
2010 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (258 KB) Click here to view/download the pdf, Page 2 of 2 (264 KB) * * * * * *...
-
Common Problems with Parking
Ø Parking garages do not have adequate vertical clearance for vans. Fully accessible parking, including a space reserved for those who use vans, is provided. ...
-
Clearances: ADA Standard Section 1002.4.4
Clearances for wheelchair spaces shall comply with 1002.4.4. EXCEPTIONS: 1. Where provided, securement devices shall be permitted to overlap required clearances. 2....
-
11B-809.10.5.1 Clear floor space
lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and knee and toe clearance...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3); • Clearance...