Given: multistory parking structure circa 1980 with limited head height for vans Issue: Can an elevator door open to and co-share/use an access aisle for an accessible parking space?...
Search Results "Centered Clear Floor Space"
-
Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
-
3.5 Gahanna Stoneridge Plaza Movies 16, 323 Stoneridge Lane, Gahanna, Ohio
- In Auditorium 4, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their current location....
-
Technical Memorandum TM 2013-18 Sinks
Sinks provided in these spaces shall be considered “kitchen” sinks....
-
T402 Ramps and Bridgeplates
technical requirements for ramps and bridgeplates in the 2016 Non-Rail Vehicle Guidelines include provisions on design load, installation and operation, emergency operation, surfaces, clear...
-
Efforts to maximize benefits
A National Center for Health Statistics (NCHS) survey also indicates that people with disabilities are potentially an untapped market for the telecommunications industry....
-
407.12.3 Forward Reach (Section-by-Section Analysis)
The proposed provision would also require the vertical reference plane to be centered on, and intersect with, the operable part....
-
APPENDIX B POLICY OF NONDISCRIMINATION ON THE BASIS OF HIV
APPENDIX B POLICY OF NONDISCRIMINATION ON THE BASIS OF HIV Consistent with the Americans with Disabilities Act (ADA), it is the policy of Union Parish Detention Center, its officers...
-
ADA Checklist for Existing Facilities: Identify barriers and develop a plan
A good resource for this task is the ADA Checklist for Existing Facilities produced by the New England ADA Center (http://www.adachecklist.org)....
-
[ADA Title II §35.151(b)(4)(i)] Primary function
Areas that contain a primary function include, but are not limited to, the dining area of a cafeteria, the meeting rooms in a conference center, as well as offices and other work areas in...
-
502.3.4 Location
Access aisles shall be permitted to be placed on either side of the parking space except for angled van parking spaces which shall have access aisles located on the passenger side of the...
-
Exception for accessible means of egress in existing buildings in IBC 2000
Accessible spaces shall be provided with not less than one accessible means of egress....
-
Readily achievable (Section-By-Section Analysis and Response to Comments)
This section makes clear that, in some instances, resources beyond those of the local facility where the barrier must be removed may be relevant in determining whether an action is readily...
-
1134A.8, Item 8
Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40 inches (1016 mm) from the floor....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground. [ECTCR UFAS 5.2]...
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
§ 1194.25(j)(2)
(2) Where any operable control is 10 inches or less behind the reference plane, the height shall be 54 inches maximum and 15 inches minimum above the floor....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
Toilets
Provide a toilet seat that is 17" to 19" above the finished floor in the north women's toilet room located in the "Celebrity Spies" exhibit area. See Standards § 4.16.3....