EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
Search Results "Clear Floor Area"
-
4.21.6 SHOWER UNIT
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
NFPA
notification appliance, or control unit enclosures (2) Single drops installed in the raceway to individual devices or appliances (3)* In a single room not exceeding 1000 ft2 (93 m2) in area...
-
NFPA
(3)*In a single room not exceeding 1000 ft2 (93 m2) in area, a drop installed in the raceway to multiple devices or appliances that does not include any emergency control function devices...
-
Non-Positive Shut-off
Remember that the hose has to be at least 59" long so it would fall onto the floor of the tub if dropped. It's a plumbing safety requirement....
- TechniSoil G3® Pathway Liquid Polymer Stabilizer
- Takeform Fusion Signage Office/Suite/Room Identification Type F
- Takeform Fusion Signage Office/Suite/Room Identification Type G
- Takeform Fusion Signage Office/Suite/Room Identification Type G.2
- Bobrick Recessed Heavy Duty Specimen Pass-Through Cabinet B-50516
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
F1
Is there an accessible route that connects the accessible entrance to areas that are likely to be used to register people as they arrive at the shelter?...
-
1133A.4.1, Item 2
Base cabinets directly under the kitchen sink counter area and work surface shall be removable as required in Section 1133A.3....
-
Recreation Site
Recreation Site—A discrete area on a national forest that provides recreation opportunities, receives use, and requires a management investment to operate and/or maintain to standard....
-
68.101(c)(5)(A) Accessible parking
(A) If parking is required as part of the lease agreement or is provided to serve the leased area, accessible parking spaces shall comply with TAS 208 and 502....