(D) require that users of telecommunications relay services pay rates no greater than the rates paid for functionally equivalent voice communication services with respect to such factors...
Search Results "Rate of Change"
-
225(d)(1)(D)
-
Energy Consumption During Ambulation
Subjects walked on each surface at their preferred pace, until the physiological variables (energy consumption, heart rate, velocity) had stabilized (2‒3 minutes) and the data collection...
- BEA Inc. MS09 Hands Free Activation Door Access (Wave to Open)
-
General: ADA Standard Section 223.1
Section 223.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for medical care and long-term care facilities.
-
711.4.1 Through penetrations
Through penetrations of fire-resistance-rated horizontal assemblies shall comply with Section 711.4.1.1 or 711.4.1.2....
-
711.3.1.2 Through-penetration firestop system
approved penetration firestop system installed as tested in accordance with ASTM E 814, with a minimum positive pressure differential of 0.01 inch (2.49 Pa) of water and shall have an F rating...
-
711.4.6 Floor fire doors
Floor fire doors used to protect openings in fire-resistance-rated floors shall be tested in the horizontal position in accordance with ASTM E 119, and shall achieve a fire-resistance rating...
-
711.3.1 Through penetrations
Through penetrations of fire-resistance-rated walls shall comply with Section 711.3.1.1 or 711.3.1.2....
-
704.10 Vertical exposure
Exception: Opening protectives are not required where the roof construction has a fire-resistance rating of not less than 1 hour for a minimum distance of 10 feet (3048 mm) from the adjoining...
-
What was measured and why?
Heart Rate and Rating of Perceived Exertion – Rating of perceived exertion (RPE) is a research scale used to document the individual’s perception of how difficult it is for his/her body...
-
11B-216.4.1 Exit doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
11B-216.4.1 Exit doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
17) Visual alarms
Flash rate must be at a minimum of 1Hz and maximum of 3Hz (§4.28.3). UFAS: Contains much less detail. Allows faster flash rate of up to 5Hz (§4.28.3)....
-
709.5 Openings
Opening protectives shall have a minimum fire-protection rating of 20 minutes....
- Endorphin 355 Series e4 Resistance System
-
Summary of Regulatory Analysis
regulatory analysis summarized in the table below shows that the estimated monetized costs of the Web site and kiosk requirements exceed their estimated monetized benefits at the 7% discount rate...
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
[See subsections ...]
-
Conclusions
We are able to state with confidence α=.05) that the 6 months of aging have significantly changed the impact performance for all systems except the unsurfaced (without an additive) EWF....
-
What proportion of the population could negotiate these surfaces?
Energy consumption, level of difficulty rating and rating of perceived exertion were evaluated to determine the proportion of our subjects who considered each surface to be “accessible.”...
-
903.3.1.1.1 Exempt locations
Sprinklers shall not be omitted from any room merely because it is damp, of fire-resistance-rated construction or contains electrical equipment....
-
Manual vs. Power (Questionnaire Data)
It should be noted that even though manual WC users had higher vibrations for all engineered surfaces, on average they rated all surfaces better than power chair users....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...