1009.4.2 Height. The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
Search Results "Coin Slot Height"
Commonly Searched Documents
-
1009.4.2 Height
-
407.12.3.2.1 Height
The height of the operable part shall conform to Table 407.12.3.2.1....
-
F216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of permanent interior...
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of permanent interior...
-
T702 Signs
[See subsections ...]
-
216.2 Designations
216.2 Designations. Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of...
-
4.1.3(16)(a)
(a) Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6.
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
Handrails [§504.6, §505]
Handrails [§504.6, §505] Handrails are required on both sides of stairs and must be continuous within the full length of each stair flight. Inside handrails on switchback or...
-
11B-707.7.2 Characters
11B-707.7.2 Characters. Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
1009.5.3 Height
1009.5.3 Height. The height of the transfer platform shall comply with 1009.4.2....
- Brewer Access™ High-Low Exam Table
-
Threshold Height
Section 404.2.5 addresses the height of thresholds....
- Bobrick ConturaSeries® Recessed Napkin/Tampon Vendor 25₵, 50₵ and Free Operation B-4706
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
1008.3.1.2 Height
1008.3.1.2 Height....
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower....
-
A. Question 1: Applicability of Section 904.4.1’s Exception
In other words, an entity satisfies Section 904.4.1 whenever it provides a sales or service counter that is of a uniform height of less than 36 inches. See generally id....
- Bobrick TrimLineSeries™ Surface-Mounted Napkin/Tampon Vendor 25₵, 50₵ and Free Operation B-370639