703.4.1 Height above Finish Floor or Ground....
Search Results "Character Height (Raised)"
-
703.4.1 Height above Finish Floor or Ground
-
11B-602.4 Spout height
11B-602.4 Spout height. Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
- Steelcase Ology Series height-adjustable tables
-
Recommendation of a 19" Lower Adjsutable Height as the Minimum Accessibility Standrds (Joint Report)
Recommendation of a 19" Lower Adjsutable Height as the Minimum Accessibility Standrds (Joint Report)...
- Seton California Code ADA Unisex Restroom Sign with ISA - Black 84951
- Seton California Code ADA Unisex Restroom Sign with ISA - Blue 84950
- Seton California Code ADA Mens Restroom Sign with ISA - Black 84947
-
How to Measure Transfer Surface Height
How to Measure Transfer Surface Height Regardless of the final decision on the low height measurement, the Subcommittee agreed that the height of the transfer surface would be measured...
- Takeform Fusion Signage Miscellaneous Room Identification Type E.2
- Teknion Journal Extended Range Height-Adjustable Table
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 11B-1005.2.1.1 Dispersion....
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 11B-1005.2.1.1 Dispersion....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface. Exception: Where a guard complying with Chapter...
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space.
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface...
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space.
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [2010 ADAS] Advisory 505.4 Height. ...
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [2010 ADAS] Advisory 505.4 Height. ...
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
11B-703.8.2 Case
Low resolution VMS characters shall be uppercase....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved. [2010 ADAS] EXCEPTION: In existing elevators, buttons shall be...