Search Results "Access Aisle Width"
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- Figure 604.5.2 Rear Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- Figure 409.4.6.2 Location of Private Residence Elevator Control Panel – Drawing from the U.S. Access Board
- Figure 405.9.1 Extended Floor or Ground Surface Edge Protection – Drawing from the U.S. Access Board
-
Willoughby Industries UW-1317-HEU-FA Series Contoured High Efficiency Urinal Front Access
Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers – Drawing from the U.S. Access Board
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Figure 404.2.4.3(c) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 404.2.4.3(b) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 406.2 Counter Slope of Surface Adjacent to Curb Ramps – Drawing from the U.S. Access Board
- Figure 609.2.2 Grab Bar Non-Circular Cross Section – Drawing from the U.S. Access Board
- Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers – Drawing from the U.S. Access Board
- Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips – Drawing from the U.S. Access Board
- Figure 608.5.1 Transfer Type Shower Compartment Control Location – Drawing from the U.S. Access Board
- Rubbermaid 7818-88 Horizontal Baby Changing Station
- Inpro Corporation JointMaster® 316 Series Single Sightline for Carpet Floor Expansion Joint Covers
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
The width of the patient scanning/imaging table (side to side) at the designated transfer location should be 28 inches minimum or the maximum extent technically feasible, but in all cases...
-
5.2.2 Transfer Surface Size Recommendations for M302
The transfer surface size has two components: width and depth. (See Figure 5.2.1.1) NPRM Proposed Provision: M302.2.2 Size....
-
Character Proportion [4.30.2]
Consider uniform stroke widths which can make signs easier to read....
-
Doors and Gates in Series [§404.2.6]
Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
If automated, such doors or gates are required to comply only with provisions for clear width and thresholds, as well as applicable provisions of the referenced ANSI/BHMA Standards....
-
§ 38.23(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch in width....
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....