Search Results "Access Aisle Width"
- Figure 608.3.1 Grab Bar for Transfer Type Showers – Drawing from the U.S. Access Board
- Figure 404.2.4.3(a) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 1002.4.4.3 Protrusions in Wheelchair Spaces in Amusement Rides – Drawing from the U.S. Access Board
- Figure 406.6 Diagonal or Corner Type Curb Ramps – Drawing from the U.S. Access Board
- Figure 1009.4.1 Clear Deck Space at Transfer Walls – Drawing from the U.S. Access Board
- Figure 1009.2.3 Clear Deck Space at Pool Lifts – Drawing from the U.S. Access Board
- Figure 1009.5.2 Clear Deck Space at Transfer Platform – Drawing from the U.S. Access Board
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.04 DC70TL-SS
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
Sec.36.304(d)(2)
Such measures include, for example, providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
M305.2.3 Height
EXCEPTION: Where the width of the transfer surface for imaging beds exceed 24 inches (610 mm), the tops of the gripping surfaces shall be permitted to be 3 inches (75 mm) minimum and 6 inches...
-
407.3.3 Numeric Keys
Some keypads will have a double width zero key and decimal key instead of the asterisk and pound signs found on a telephone keypad. These examples conform to this provision....
-
Clear Floor Space [4.19.3]
Additional width is required where the clear floor space is obstructed on both sides more than 2 feet (see page 17)....
-
1015.3 Viewing Space
The viewing space is required to be 32 inches maximum and 51 inches minimum high above the ground and extend the full width of the clear ground space....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
recommendation A transfer support (for transfer surfaces less than or equal to 24” deep) is to extend horizontally along the side of the patient scanning/imaging table at least the minimum width...
-
Design Criteria for the Transfer Station
The station was designed to investigate the impact handhelds, back rests, heights, and seat widths have on transfer performance....
-
R306.3.1 Separation
European and Australian roundabouts provide a 610 mm (24 inch) width of tactile surface treatment from the centerline of the curb ramp or blended transition across the full width of the...
-
4.9.4 HANDRAILS
Figure 19 Stair Handrails (2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of...
-
Station 2-Three-Point Turn
Designers can use this information to select shared use path widths and, if necessary, build wider turnaround areas, so that users can execute U-turns within the confines of the path....
-
11B-603.2.3 Door swing
Other than the door to the accessible water closet compartment, a door in any position, may encroach into the turning space by 12 inches (305 mm) maximum....
- USDA Forest Service Accessibility Guidebook for Ski Areas Operating on Public Lands
-
1012.3 Opening limitations
At elevated walking surfaces for access to and use of electrical, mechanical or plumbing systems or equipment, guards shall have balusters or be of solid materials such that a sphere with...
- Hoyer Journey Stand-Up Lift