However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit overhangs of natural protruding objects....
Search Results "Clear Floor Area"
-
Protruding Object
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the recreation access route....
-
Protruding Object
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit overhangs of natural protruding objects....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
- ADA Helper App
-
11B-201.1 Scope
All areas of newly designed and newly constructed buildings and facilities and altered portions of existing buildings and facilities shall comply with these requirements....
-
General: ADA Standard Section 234.1
Section 234.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for amusement rides.
-
11B-234.3 Minimum number
These rides are not exempt from the other provisions in Section 11B-234 requiring an accessible route to the load and unload areas and to the ride....
-
11B-234.3 Minimum number
These rides are not exempt from the other provisions in Section 11B-234 requiring an accessible route to the load and unload areas and to the ride....
-
11B-201.1 Scope
All areas of newly designed and newly constructed buildings and facilities and altered portions of existing buildings and facilities shall comply with these requirements....
- American Standard Madera 1.28 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System
- American Standard Madera 1.6 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
- American Standard Madera 1.28 gpf EverClean Toilet with Exposed Manual Flush Valve System
-
Mastering the Cosmic Gauntlet: Your Guide to Run 3
What was once a wall becomes your new floor....
-
https://www.facebook.com/AERIOQPortableAirConditioner/
Unlike traditional floor-standing air conditioners, AERIOQ is primarily designed for wall mounting, although some versions can also be placed on a tabletop....
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
Level boarding bus system
designated stops have boarding platforms and the design of boarding platforms and non-rail vehicles are coordinated to provide boarding having little or no change in level between the vehicle floor...
-
Signage (slide 11)
They really should be solid at floor level, and, not shadowed, as you [lean in to read]. Auditory signs can be an option....
-
407.8.2.1 Unobstructed Side Reach
part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
408.2 Visibility
Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
408.1 General
Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...