Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Stds 4.1.3(7), 4.13.5] Yes _____ No _____...
Search Results "Measuring Technique"
-
7a.
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
§ 38.159(b)(6) Platform surface
The platform shall have a minimum clear width of 28 1/2 inches (725 mm) at the platform, a minimum clear width of 30 inches (760 mm) measured from 2 inches (50 mm) above the platform surface...
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
Introduction
In Phase I, processing techniques and material properties were evaluated in small benchtop and full-depth laboratory tests (Laufenberg and others 2003)....
-
Purpose and function—missing the point
For more examples of how to convey the purpose and function of images with alternate text, see “Appropriate Use of Alternative Text” (http://webaim.org/techniques/alttext/) from WebAIM....
-
Recreational Facilities
If you use passcard-style keys for recreation areas, you should make those keys accessible to people who are blind or who have low vision, using the simple techniques described in “Check-In...
-
3.2 Microphone Location
It is easier to control microphone positioning when only one talker is involved, but even so optimal microphone technique cannot be taken for granted (Ross 1991)....
-
Introduction
True “construction industry tolerances” as defined by the ADA Standards, should not be confused with another concept that we call “Acceptable Measurements.” ...
-
Conclusions
Our analysis based on static anthropometry measurements. It focuses solely on the adequacy of these transfer surface dimensions for a static seating surface....
-
1013.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. ...
-
3. Terminology
3.1 Definitions: 3.1.1 Terminology used in this practice conforms to the definitions included in Terminology E867. 3.1.1.1 longitudinal profile measurement, n—a series of elevation...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
11B-603.6 Guest room toilet and bathing rooms
that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring...
- OPENspace
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Blended Transitions (R304.4) (Section-by-Section Analysis)
The running slope is measured parallel to the direction of pedestrian travel....
-
702.5.1 ANSI/IEEE C63.19-2011
American National Standard for Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids, May 27, 2011, IBR approved for Appendix C, Section 412.3.1...
-
g-i
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Standards §§ 4.1.3(7), 4.13.5] Yes No...