TIA 1083 (2007), Telephone Terminal Equipment Handset Magnetic Measurement Procedures and Performance Requirements, would be incorporated by reference at 410.4.2....
Search Results "Measuring Technique"
-
E102.8 TIA (Section-by-Section Analysis)
-
C102.3 American National Standards Institute/ Institute of Electrical and Electronics Engineers (ANSI/IEEE)
ANSI/IEEE C63.19-2011 American National Standard for Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids, Committee C63 – Electromagnetic Compatibility...
-
10.2.1(1)
new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96 inches (measured...
-
E102.3 American National Standards Institute/ Institute of Electrical and Electronics Engineers (ANSI/IEEE)
ANSI/IEEE C63.19-2011 American National Standard for Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids, Committee C63 – Electromagnetic Compatibility...
-
4. Summary of Practice
4.1 This practice was developed specifically for estimating pathway roughness from longitudinal profile measurements. 4.2 Longitudinal profile measurements for one wheel track are transformed...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
School Districts' Standards and Procedures
Specifically, the evaluation standards and procedures must ensure that: Evaluations consist of more than IQ tests;55 Evaluations measure specific areas of educational need...
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
Completing the Checklist
If the measurement or number falls short of that required for accessibility, write the measurement or number to the right of the question in the area under “Comments.”...
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
References:
IDeA Center (Buffalo Study) wheelbase measurements on wheeled mobility devices...
-
12102(4)(E)(ii)
(ii) The ameliorative effects of the mitigating measures of ordinary eyeglasses or contact lenses shall be considered in determining whether an impairment substantially limits a major life...
-
§100.143(e)
Not every corrective measure listed in paragraph (d) of this section need be taken for each likely violation....
-
§ 38.107(a)(2)
(2) The height of the water closet shall be 17 inches to 19 inches measured to the top of the toilet seat. Seats shall not be sprung to return to a lifted position....
-
§ 38.123(a)(2)
(2) The height of the water closet shall be 17 inches to 19 inches measured to the top of the toilet seat. Seats shall not be sprung to return to a lifted position....
-
§ 38.157(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread....
- Doorbell Factory Round Stainless Steel Doorbell
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
5.8.2.5 Toe Height
The toe height should be 18 inches minimum, measured above the ground when the top of the breast platform is 34 inches above the ground....
-
T402.8.2 Deployment to Boarding Platforms
The running slope of ramps and bridgeplates used for deployment to platforms shall be 1:8 maximum, as measured to the boarding platform with the non-rail vehicle resting on a flat surface...
-
2a
Do large showers measure at least 30" wide by 60" deep as shown in Figure 35(b) below?...
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....