• Each bank of public telephones must have one or more wheelchair accessible telephones and these and other public telephones must have the ability to amplify the volume at the handset....
Search Results "Local Access Code"
-
Each bank of public telephones must have one or more wheelchair accessible telephones and these and other public telephones must have the ability to amplify the volume at the handset.
-
DEFINITION: SERVICE ANIMAL
FIND IT IN THE REGULATIONS: State and Local Governments: §35.104 definition and §35.136 service animals Places of Public Accommodation: §36.104 definition and §36.302 (c) service animals...
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope....
-
Health Care Providers
See Access to Medical Care for Individuals with Mobility Disabilities available at: http://www.ada.gov/medcare_ta.htm....
-
Health Care Providers
See Access to Medical Care for Individuals with Mobility Disabilities available at: http://www.ada.gov/medcare_ta.htm....
-
382.21 May carriers limit access to transportation on the basis that a passenger has a communicable disease or other medical condition?
382.21 May carriers limit access to transportation on the basis that a passenger has a communicable disease or other medical condition?...
-
D. Beyond TTYs: Providing 9-1-1 and Emergency Services Via New Communication Technologies
Some people who have hearing disabilities do not have access to TTYs....
-
Construction and Manufacturing Tolerances: ADA Standard Section 104.1.1
Section 104.1.1 of the ADA Standards covers the most current information on dimensions in regards to construction and manufacturing tolerances in the ADA Standards.
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
§382.133(g)
(g) In the case of a codeshare itinerary, the carrier whose code is used on the flight must either inform the individual inquiring about using a ventilator, respirator, CPAP machine or POC...
-
Self-Closing Faucets
Commenters indicated that "metering" is a descriptor that is more accurate and consistent with plumbing codes. Response....
-
202.6 Architectural Barrier Removal
Removal of architectural barriers, pursuant to 28 C.F.R. s. 36.304, from buildings, structures or facilities shall comply with this code’s requirements for alterations unless compliance...
-
How is “technical infeasibility” determined in an alteration?
Examples include work that would impact a facility’s structural frame or that would conflict with applicable codes or building requirements....
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts, referred to as support rails in the California Building Code, are not required to comply with the requirements for handrails on walking...
-
101.3 Intent
The purpose of this code is to establish the minimum requirements to safeguard the public health, safety and general welfare through structural strength, means of egress facilities, stability...
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
-
Other Requirements in the ADA Standards
Platform Lifts Platform lifts, where permitted on an accessible means of egress, must have standby power (§207.2). ...
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
- Spectrum Aquatics Summit 500BP Therapy Pool Lift (Battery Powered)
-
1118B.6
FIGURE 11B-5D -- SIDE REACH ETA Editor's Note Select portions of the 2010 California Building Code (2010 CBC) are provided for reference only....
-
B.6.ii. - If an agency determines that the acquisition of EIT that meets the applicable technical provisions of the Access Board’s standards would impose an undue burden, does it have any remaining obligations under Section 508?
The statute requires that the information and data be provided to individuals with disabilities by an alternative means of access....