The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
Search Results "Clear Floor Area"
Commonly Searched Documents
-
1134A.8, Item 1
-
407.8.2.2 Obstructed Side Reach
more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches (1170 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
4.27.3* Height
Electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
Plumbed Fixtures
Non-fixed units, such as bottled water coolers, are recognized as an option in providing additional access where only one fixed unit is provided on a floor....
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
11B-608.5.1 Reserved
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
(1)(c)
long should be mounted on at least one side wall, with one end not more than 12 inches (305 mm) from the back wall, at a height between 33 inches (840 mm) and 36 inches (915 mm) above the floor...
-
[2010 ADAS] 105.2.5 NFPA
have no clear interior partitions and the 10 ft distances would prohibit the placement of a smoke alarm or smoke detector required by other sections of the code....
-
1005.3 Edge Protection
platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull into a clear...
-
§35.163 Information and Signage
Several commenters requested that, where TDD-equipped pay phones or portable TDD’s exist, clear signage should be posted indicating the location of the TDD....
-
1005.3 Edge Protection
platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull into a clear...
-
1005.3 Edge Protection
platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull into a clear...
-
Platform Size and Surface
Platform Size and Surface To be part of an accessible route, lift platforms must provide the amount of clear space required for wheelchairs in ADAAG 4.2.4....
-
R402.3 Post-Mounted Objects
Where objects are mounted between posts or pylons and the clear distance between the posts or pylons is greater than 305mm (1.0 ft), the lowest edge of the object shall be 685 mm (2.25 ft...
-
11B-707.3 Operable parts
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation. Exceptions: 1....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
§382.117(b)
(b) You must permit the service animal to accompany the passenger with a disability at any seat in which the passenger sits, unless the animal obstructs an aisle or other area that must...
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
202.2 Additions
Each addition that affects or could affect the usability of or access to an area containing a primary function shall comply with 202.4....
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior...
-
Program Accessibility
who meet the criteria, including people who have disabilities, the opportunity to participate in a program (an activity in which someone may participate or the reason someone visits an area...
-
Trail Managed Use
Trail Managed Use—Any mode of travel that is actively managed and appropriate for a specific trail or area, based on its design and management....