Search Results "Clear Floor Area"
Commonly Searched Documents
-
Scenario 8 – Accessibility
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
11B-604.8.1.1 Size
shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and 59 inches (1499 mm) deep minimum for floor...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
Voluntary Barrier Removal vs required Barrier Removal
If an existing 2 story retail building which is exempt from installing an elevator chooses to do so, is he exempt from POT upgrades for altered areas?...
-
Visual Alarms
Visual Alarms • Where audible fire alarms or emergency notification is provided, flashing lights are required in public and common use areas, including toilet and bath rooms, locker rooms...
-
§ 36.302(f)(3) Identification of accessible seating
companion seats shall be identified on seating maps, plans, brochures, or other information provided to the general public to describe the seating layout or configurations at an assembly area...
-
209.5 Mechanical Access Parking Garages
Mechanical access parking garages shall provide at least one passenger loading zone complying with 503 at vehicle drop-off and vehicle pick-up areas....
-
Sec.36.403(h)(1)
(1) The obligation to provide an accessible path of travel may not be evaded by performing a series of small alterations to the area served by a single path of travel if those alterations...
-
6.1(1)
(1) Hospitals - general purpose hospitals, psychiatric facilities, detoxification facilities -- At least 10 percent of patient bedrooms and toilets, and all public use and common use areas...
-
Recreation Site
An area that is improved, developed, or otherwise identified for recreation and that has a development scale of 0, 1, 2, 3, 4, or 5 (See Forest Service Handbook 2309.13, Chapter 10 – Exhibit...
-
Limited Access Spaces (§203.4)
Limited Access Spaces (§203.4) Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways Examples: lighting/ equipment catwalks at stages and performing areas...
-
Elongated surface openings must be perpendicular to the dominant direction of travel, but what if there is no dominant direction of travel?
Where space allows accessible routes to completely bypass the area with openings, elongated openings can be oriented in either direction....
-
§ 37.33(b)
(b) Fixed-route transportation systems operated by public airport operators between the airport and a limited number of destinations in the area it serves are subject to the provisions of...
-
§ 37.155(a)(10)
(10) Unique circumstances in the submitting entity's area that affect the ability of the entity to provide paratransit, that militate against the need to provide paratransit, or in some...
- Neo-Metro Metaal Toilet Configured for In-Wall Flushing System
- Cybex Total Access Arc Trainer
-
ACCESSIBLE ROUTE
Interior accessible routes may include corridors, hallways, floors, ramps, elevators and lifts....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...