In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
Search Results "User Control"
-
11B-608.5.3 Alternate roll-in type shower compartments
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL...
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
Are locks operated by keys prohibited due to the pinching or twisting of the wrist their operation typically requires?
No, non-fixed portions of door or gate hardware, including keys and access cards, are not covered by the Standards, but those that can be used without pinching or turning will...
-
Pay Stations
Pay stations and other elements that serve accessible parking spaces must comply with requirements for operable parts (§309) and be served by an accessible route. Require-ments [sic]...
-
§382.57(c)(3)(ii) Timing
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
§ 1194.23(g)
(g) If the telecommunications product allows a user to adjust the receive volume, a function shall be provided to automatically reset the volume to the default level after every use....
-
§ 382.57(c)(3)(ii) Timing
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
F213.2 Toilet Rooms and Bathing Rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required...
-
213.2 Toilet Rooms and Bathing Rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required...
-
213.2 Toilet Rooms and Bathing Rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required...
- Automatic Curtain Ltd. Remote Controlled Automatic Roller Shade System I
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
407.3.1 Tactilely Discernible
Input controls shall be operable by touch and tactilely discernible without activation....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
10.4.1(1)
such as ramps, elevators or other vertical circulation devices, ticketing areas, security checkpoints, or passenger waiting areas shall be placed to minimize the distance which wheelchair users...
- Automatic Curtain, Ltd. Remote Controlled Automatic Roller Shade System II
- BTX Intelligent Fashion Motorized Drapery Systems
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
-
7.4.12.2 Gate Hardware
Gate hardware shall comply with operable controls requirements in ABAAS section 309.4 and 404.2.7....