Control buttons shall be identified by tactile characters complying with 703.2....
Search Results "User Control"
-
407.4.7.1.1 Type
-
11B-602.3 Operable parts
shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic electronically controlled...
-
11B-602.3 Operable parts
shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic electronically controlled...
-
T304 Operable Parts
A commenter to the 2008 Draft Revised Vehicle Guidelines noted that some operable parts—such as those on stop request devices—are small and difficult to reach for some transit users....
-
4.31.5* EQUIPMENT FOR HEARING IMPAIRED PEOPLE
Volume controls shall be provided in accordance with 4.1.2....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-213.2 Toilet rooms and bathing rooms
These requirements allow use of unisex (or single-user) toilet rooms in alterations when technical infeasibility can be demonstrated....
-
11B-213.2 Toilet rooms and bathing rooms
Where multiple single user toilet rooms are clustered at a single location, 50 percent, but no fewer than one, of the single user toilet rooms for each use at each cluster shall comply with...
-
Input: ADA Standard Section 707.6
Input devices shall comply with 707.6.
-
Operable Parts: ADA Standard Section 602.3
Section 602.3 covers the current ADA Standards for the operable parts of drinking fountains.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons....
-
4.6.2 Operable Parts
Controls and operating mechanisms for telescopes and periscopes that are useable from a seated position shall comply with the operable parts requirements in sections 308 and 309.4 of the...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons....
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons....
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
407.1 General (Section-by-Section Analysis)
407.1 General (Section-by-Section Analysis) This section addresses accessibility features of operable parts—such as keys and controls—when part of the user interface is hardware....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
APPENDIX C
APPENDIX C Diseases Transmitted Through the Food Supply (Issued by the Centers for Disease Control, U.S....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....