5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
Search Results "Pull Side"
Commonly Searched Documents
- 
    
  
  5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
 - 
    
  
  Supports (M301.3, M302.3, and M305.2)
  
M301.3, M302.3, and M305.2 provide technical criteria for transfer and positioning supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic...
 - 
    
  
  5.6.1 Stirrups Provision for M301
  
5.6.1 Stirrups Provision for M301 NPRM Description: For patients with limited leg strength and control, thigh, knee and calf supports are necessary to maintain an appropriate...
 - 
    
  
  4.27.3* Height
  
The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
 - 
    
  
  4.31.3* Mounting Height
  
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
 - 
    
  
  4.34.3(3) Forward and Parallel Approach
  
(3) Forward and Parallel Approach. If both a forward and parallel approach are possible, operable parts of controls shall be placed within at least one of the reach ranges in...
 - 
    
  
  B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
  
In the final rule M301 and M302 provide the technical requirements for diagnostic equipment used in the supine, prone, or side-lying position, and diagnostic equipment used by patients in...
 - 
    
  
  5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
 - Figure 404.2.4.3(a) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
 - 
    
  
  5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
  
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
 - 
    
  
  11B-406.5.10 Diagonal curb ramps
  
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
 - 
    
  
  5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
 - Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings
 - 
    
  
  Built-Up Curb Ramps
  
Built-Up Curb Ramp with Side Flares Recommendations: Provide edge protection along the sides of built-up curb ramps to prevent tipping hazards....
 - 
    
  
  § 38.123(a)(3)
  
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
 - Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors – Drawing from the U.S. Access Board
 - Delta 1-1/2″ x 42″ ADA Grab Bar Concealed Mounting 40142-SS
 - 
    
  
  (1)(c)
  
(c) A grab bar at least 24 inches (610 mm) long should be mounted behind the water closet, and a horizontal grab bar at least 40 inches (1015 mm) long should be mounted on at least one side...
 - Don-Jo Mfg., Inc. 5" Hospital Latch 4550
 - Don-Jo Mfg., Inc. 2-3/4" Hospital Latch 4500
 - 
    
  
  Other Requirements in the ADA Standards
  
Operable Parts Operable parts used by building occupants, including alarms pulls and hardware for fire extinguisher cabinets, must comply (§205, §309)....
 - 
    
  
  5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
 - 
    
  
  1. Transfer Surface
  
[See subsections ...]