A grab bar 12 inches long minimum shall be installed on the head end wall at the front edge of the bathtub....
Search Results "Edge Protection"
Commonly Searched Documents
-
11B-607.4.2.3 Head end wall
-
4.26.4 Eliminating Hazards
Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
Location Above Detectable Elements
Objects located above elements that are within can sweep can protrude 4” maximum from the leading edge of such elements provided that any required reach or clear floor space is not obstructed...
-
4.26.4 ELIMINATING HAZARDS
Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
When door vision lights are limited to 100 square inches by the fire code, is compliance with the specified maximum height of 43” to the bottom edge still required?
Yes. The Standards do not exempt such doors from the requirement for vision lights (§404.2.11). However, compliance is not required when the lowest part of the vision light is more...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
Clear With [sic] [§404.2.3]
Clear With [sic] [§404.2.3] The clear width is measured from the stop to the face of doors or gates open 90⁰ (or to the leading edge of sliding or folding doors....
-
§ 38.153(b)
(b) All step edges shall have a band of color(s) running the full width of the step which contrasts from the step tread and riser, either dark-on-light or light-on-dark....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Seats
In the raised (load) position, the centerline of the seat must be located over the deck, a minimum of 16 inches from the edge of the pool....
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
The Committee recommends gripping surfaces be free of sharp or abrasive elements and have rounded edges....
-
1132A.9 Smooth surface
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other and be free of sharp or abrasive edges....
-
4.4.1* General
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
4.7.10 Diagonal Curb Ramps
If diagonal (or corner type) curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to the direction of pedestrian flow....
-
1.1.12 Ramp cross slope
Measure for overall cross slope of ramps by establishing elevations at the extreme edges of the ramp at the top and bottom of the ramp and calculate the cross slope at these two locations...
-
12209(a)(2)(A) In General
--The rights and protections under this Act shall, subject to subparagraph (B), apply with respect to the conduct of the Senate regarding matters other than employment....
-
§382.159(a)(2)
(2) Writing to Department of Transportation, Aviation Consumer Protection Division (C-75), 1200 New Jersey Avenue, SE., Washington, DC 20590....
- BTX Intelligent Fashion Tumo Programming Reverse Motor Direction
-
704.10 Vertical exposure
For buildings on the same lot, approved protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent...
-
907.2.6.2.3 Smoke detectors
Exceptions: Other approved smoke-detection arrangements providing equivalent protection including, but not limited to, placing detectors in exhaust ducts from cells or behind protective...
-
§ 36.101(b) Broad coverage
The primary purpose of the ADA Amendments Act is to make it easier for people with disabilities to obtain protection under the ADA....
-
§ 35.101(b) Broad coverage
The primary purpose of the ADA Amendments Act is to make it easier for people with disabilities to obtain protection under the ADA....