Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
Search Results "Doors in Series"
Commonly Searched Documents
- 
    
  
  (1)(e)
  
- 
    
  
  Are doors or gates to employee work areas required to comply?
  Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior.... 
- 
    
  
  11B-604.8.1.1.2 Maneuvering space with side-opening door
  11B-604.8.1.1.2 Maneuvering space with side-opening door.... 
- 
    
  
  11B-408.3.2.2 Duration
  Power-operated swinging doors shall remain open for 20 seconds minimum when activated.... 
- 
    
  
  11B-604.8.1.1.2 Maneuvering space with side-opening door
  In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep... 
- Yale 4400 Series Institutional Door Closer
- 
    
  
  D4. Door Clearance
  On the pull side of the door, is there at least 18 inches clearance provided to the side of the latch if the door is not automatic or power-operated?... 
- 
    
  
  (4) Doors to public and common use areas
  The final Guidelines continued to provide that on accessible routes in public and common use areas, and for primary entry doors to covered units, doors that comply with ANSI 4.13 meet the... 
- 
    
  
  2.2 Entrances
  Can the accessible entrance be used independently, or is the door heavy or usually locked? Is the entrance door at least 32 inches wide?... 
- Trimco 1074 Series ADA Barn Door Lock
- 
    
  
  A4.10.6 Door Protective and Reopening Device
  The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close.... 
- 
    
  
  A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
  The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close.... 
- 
    
  
  407.3.3.1 Height
  The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor. 
- 
    
  
  407.3.3.1 Height
  The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor. 
- 
    
  
  M3
  M3. Is the hardware (e.g., lever, pull, etc.) usable with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.13.9] Yes No If No,... 
- 
    
  
  407.3.3.1 Height
  407.3.3.1 Height. The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish... 
- 
    
  
  11B-407.3.3.1 Height
  The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor. 
- 
    
  
  11B-407.3.3.1 Height
  The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor. 
- 
    
  
  11B-407.3.3.1 Height
  The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor. 
- 
    
  
  4.10.6* Door Protective and Reopening Device
  Elevator doors shall open and close automatically.... 
- 
    
  
  307.4 Vertical Clearance
  EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground.... 
- 
    
  
  11B-307.4 Vertical clearance
  Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ... 