Exception:  Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground.  ...
Search Results "Doors in Series"
Commonly Searched Documents
-
11B-307.4 Vertical clearance
-
D3
[ADA Standards § 4.13.9]    Yes    No If No, leave door propped open, add new accessible hardware, or adapt/replace hardware.  ...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- FlexCounterâ„¢ - Window Door Combination
- Sargent 351 Series Aluminum Door Closer
-
Remove post (increase clear width at double leaf doors)
[See subsections ...]
- Hager Companies 5200 Series - Heavy Duty Door Closer
- LaCantina Doors - Contemporary Clad Industrial
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
g-ii
Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able to easily...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...
-
Visual Notification Devices
Visual Notification Devices Care must be taken that notification devices intended to signal a door knock or bell are separately wired....
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
- Sargent 1431 Series Aluminum Door Closer
-
Power Operation: ADA Standard Section 408.3.2.1
Section 408.3.2.1 covers the current ADA Standards for the power operation of swinging doors on limited-use/limited-application elevators.
- NYC Board of Elections: Video 3 - Accessibility Clerk Responsibilities
- Allegion LCN 1460 Series Surface Mounted Door Control