Regarding maneuvering space around the bed(s) in the accessible guestrooms... ...in accessible guestrooms with one bed, is there at least a 36" wide route on each side of the bed to allow...
Search Results "Door Maneuvering Clearance"
Commonly Searched Documents
-
J. Bedside Clearance
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
Seating [4.32.2] and Knee Clearance [4.32.3]
Seating [4.32.2] and Knee Clearance [4.32.3] Knee space at least 27 inches high is required for a depth of 19 inches....
-
11B-404.2.1 Revolving doors, gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.2.1 Revolving doors, gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.2.1 Revolving doors, gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
3.3.6 Knee Clearance Height, minimum
3.3.6 Knee Clearance Height, minimum Knee clearance heights for the four sets of standards range from 650 mm (25.6 in.) (Australia) to 700 mm (27.6 in.) (U.K.) (Figure 3‒6)....
-
3.3.7 Toe Clearance Height, minimum
3.3.7 Toe Clearance Height, minimum There is relatively large disparity between the standards for toe clearance height, with the U.S. having the lowest (230 mm or 9 in.), followed by...
-
Forward Approach: ADA Standard Section 904.4.2
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided. Knee and toe space complying with 306 shall be...
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided. Knee and toe space complying with Section 11B-306...
-
Minimum Clear Opening
Other commenters stated that, generally, door width should provide a 32-inch clear opening, but that this width can be reduced if sufficient maneuvering space is provided at the door....
-
3.3.8 Knee Clearance Depth, minimum
3.3.8 Knee Clearance Depth, minimum Knee clearance depths for the four sets of standards range from 200 mm (8 in.) in Canada to 280 mm (11 in.) in the U.S. (Figure 3‒8)....
-
3.3.9 Toe Clearance Depth, minimum
3.3.9 Toe Clearance Depth, minimum Toe clearance depths for the standards range from 150 mm (6 in.) in the U.S. to 230 mm (9 in.) in Canada (Figure 3‒9)....
-
4.34.2(2)
(2) Accessible spaces shall have maneuvering space complying with 4.2.2 and 4.2.3 and surfaces complying with 4.5....
-
4.13.11(2)(a)
(a) exterior hinged doors: (Reserved)....
-
408.3 Elevator Doors
408.3 Elevator Doors. Elevator hoistway doors shall comply with 408.3....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
2. Door Hardware
Is the bathroom door hardware (levers, pulls, etc.) easily operable with one hand, without tight grasping, pinching or twisting of the wrist, since many persons with disabilities may not...
-
408.3.1 Sliding Doors
408.3.1 Sliding Doors. Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
408.3.2 Swinging Doors
408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....