Doors, doorways, and gates providing user passage shall be provided in accordance with F206.5....
Search Results "Door Maneuvering Clearance"
-
F206.5 Doors, Doorways, and Gates
-
206.5 Doors, Doorways, and Gates
Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5....
-
Doors, Doorways and Gates [§206.5 and §404]
Doors, Doorways and Gates [§206.5 and §404] Compliance is required for doors, doorways, and gates providing user passage on accessible routes....
-
18.1 Q. Is it necessary to provide usable doors when the door leads to an area of the dwelling that is not accessible, such as the door leading down to an unfinished basement...?
Within the dwelling unit, doors intended for user passage through the unit must meet the requirements for usable doors....
-
R218 Doors, Doorways, and Gates
R218 Doors, Doorways, and Gates The SNPRM would revise R218 to read as follows: R218 Doors, Doorways, and Gates....
-
1010.2.2 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
1010.2.2 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Minimum Required Depth: ADA Standard Section 306.3.3
Section 306.3.3 covers the current ADA Standards for the minimum required depth for knee clearance.
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....
-
Knee and Toe Clearance
Accessible lavatories and sinks must provide knee and toe clearance for a forward approach (606.2)....
-
Maximum Depth: ADA Standard Section 306.2.2
Section 306.2.2 covers the current ADA Standards for the maximum depth for toe clearance.
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. ...
-
1132A.3 Width and height of interior doors and secondary exterior doors
1132A.3 Width and height of interior doors and secondary exterior doors. Doors shall comply with the following:...
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
Maximum Depth: ADA Standard Section 306.3.2
Section 306.3.2 covers the current ADA Standards for the maximum depth for knee clearance.
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
305.4 Knee and Toe Clearance
305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....