There are other differences between the two sets of standards, including requirements for accessible windows, alterations, kitchens, an accessible route throughout a unit, and clear floor...
Search Results "Water Closet Clear Floor Space"
-
Section 36.406(e) Housing at a Place of Education
-
Scoping [4.1.2(1), 4.1.3(1)] and Location [4.3.2]
Clear width, surface texture, running and cross slope, and the treatment of changes in level help determine the usability of walking surfaces by people with mobility impairments....
-
§ 36.303(f)(3)
(3) A clear, audible transmission of voices; and...
-
§ 35.160(d)(3)
(3) A clear, audible transmission of voices; and...
-
Gangways
routes to connect accessible boat slips on floating piers, the following exceptions to the ADAAG accessible route provisions have been included in the guidelines to deal with the varying water...
-
Cross Slope [1017.7.2]
Some cross slope is necessary to provide drainage and to keep water from ponding and damaging the trail surface, especially on unpaved or natural surfaces....
-
Thresholds at Doorways [4.13.8]
ADAAG specifies a maximum threshold height of ½ inch, but allows a height up to ¾ inch at exterior sliding doors where necessary to prevent water damage....
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-216.3 Directional and informational signs
Signs that provide direction to or information about interior and exterior spaces and facilities of the site shall comply with Section 11B-703.5....
-
11B-216.3 Directional and informational signs
Signs that provide direction to or information about interior and exterior spaces and facilities of the site shall comply with Section 11B-703.5....
- Inclusion Solutions Paint Marking Stick
- Panda S.10 All Aluminum Lift & Slide System
- Gamco Automatic Wall-Mounted Foam Soap Dispenser - G-950FA
-
§1630.1(a) Purpose
The ADA as amended, and these regulations, are intended to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities,...
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...