The facility housing a “shopping center or shopping mall” only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use by...
Search Results "Water Closet Clear Floor Space"
-
Shopping Center or Shopping Mall
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
4.19.6* MIRRORS
Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) from the floor (see Fig. 31)....
-
Location: ADA Standard Section 407.4.7.1.2
Section 407.4.7.1.2 covers the current ADA Standards for the location of designations and indicators on elevator car control buttons.
-
Bradley Grab Bars 1 1/4" with Concealed Mounting 832 136 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 124 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Whitehall Mfg. 24" Grab Bar Flat Closure Plate
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1) and shall have a clear...
-
11B-708.4 Residential dwelling unit communication systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with Section 11B-708.4....
-
F202.6.3.1 Multiple Facilities
At least one toilet facility or bathing facility for each sex on each floor that has toilet facilities or bathing facilities shall comply with F213.2 and F213.3....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
306.3.2 Maximum Depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground....
-
11B-502.8 Additional signs
shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space...
-
Paperwork Reduction Act
The Paperwork Reduction Act of 1980 (PRA), 44 U.S.C. 3501 et seq., requires agencies to clear forms and record keeping requirements with OMB before they can be introduced. ...
-
Sec.36.401(d)(1)(ii)(B)
The facility housing a "shopping center or shopping mall'' only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use...
-
M303.4.1 Breast Platform Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a mammography breast platform height range of 30 inches high minimum and 42 inches high maximum above the floor....
-
§ 36.401(d)(1)(ii)(B)
The facility housing a "shopping center or shopping mall" only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use by...
-
Signage [4.6.4]
Accessible spaces must be designated by the access symbol, which can be mounted on walls, posts, or from garage ceilings so that it is not obscured by vehicles parked in the space....
- Whitehall Mfg. 24" Grab Bar Flat Closure Plate
-
Feature 2 - Routes to the Building Entrance
There must be at least one exterior accessible route that connects accessible parking spaces and other accessible elements within the site, such as accessible drop-off areas or a route from...