The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4. ...
Search Results "Obstructed Reach"
-
5.1.9 Doors
-
4.34.5.6 BATHTUB AND SHOWER ENCLOSURES
Enclosures for bathtubs or shower stalls shall not obstruct controls or transfer from wheelchairs onto shower or bathtub seats....
-
11B-804.6.3 Dishwasher
The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-804.6.3 Dishwasher
The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
BS8300:2001 Research
Reach ranges were measured using a fixed counter height at 750 mm and at three angles of arm reach with respect to the counter....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
307.3 Post-Mounted Objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
- Olympia i2 Single Handle Lavatory Faucet L-6051
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
804.6.3 Dishwasher
The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink....
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
M302.3.2 Armrests
Armrests on transfer sides are not permitted to obstruct access to the transfer surface. See M302.2.3 Exception....
-
Seating [4.32.2] and Knee Clearance [4.32.3]
The over-the-surface reach is limited to 25 inches if at least this much space is available below for knees and toes; (the forward seated reach may not extend beyond the toes)....
-
307.3 Post-Mounted Objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
Handrails
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops and sides....