Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
Search Results "Obstructed Reach"
-
f-v
-
California: Toilet Grab Bars - Uneven height allowed?
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
e-iv
Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12 (3)] Yes No...
-
11B-904.2 Approach
the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach...
-
11B-904.2 Approach
the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach...
-
M307 Operable Parts (Section-by-Section Analysis)
and ABA Accessibility Guidelines for an unobstructed forward reach or side reach for the operable parts provision....
-
10 [§ 4.7.5]
A curb ramp may have returned curbs if it has non-walking surfaces (such as grass) or obstructions on both sides because these conditions would normally discourage pedestrians from walking...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
5.5.1 Armrest Provision for Equipment Used by Patient in Seated Position
Armrests are not required but if provided cannot obstruct transfer supports....
-
Transfer Steps: ADA Standard Section 1009.5.4
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
- S. R. Smith Splash! Pool Lift
-
11B-226.4 Baby changing tables
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
§ 38.33 Fare box
Where provided, the fare box shall be located as far forward as practicable and shall not obstruct traffic in the vestibule, especially wheelchairs or mobility aids....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. ◼...
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. ◼...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...