In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
Search Results "Compartment Depth"
-
11B-608.5.3 Alternate roll-in type shower compartments
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
Check-Out Aisles and Sales and Service Counters
Section 904.4 of the 2010 Standards also clarifies that the accessible portion of the counter must extend the same depth as the sales or service counter top....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Verify Framing
Grab bar backing in toilet/shower rooms. 11B-604.5, 11B-607.4, 11B-608.3 Backing for grab bars in bathtub/shower rooms. 11B-610 Width and depth...
-
Verify Framing
Grab bar backing in toilet/shower rooms. 11B-604.5, 11B-607.4, 11B-608.3 Backing for grab bars in bathtub/shower rooms. 11B-610 Width and depth...
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
Transfer Compartments
Seats are required in transfer compartments and roll-in showers in transient lodging guest rooms (608.4)....
-
11B-602.8 Depth
11B-602.8 Depth. Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
802.1.3 Depth
Figure 802.1.3 Depth of Wheelchair Spaces in Assembly Areas...
-
F213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal. Unisex bathing rooms shall contain one shower...
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal. Unisex bathing rooms shall contain one shower...
-
7(2)(b)(vii)
(vii) Stall showers in the bathroom may be of any size or configuration. A minimum clear floor space 2'6" wide by 4'0" should be available outside the stall. (See Figure 7(d).) If...
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms. Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one...
-
2.3 Restrooms
Are the restrooms accessible? Is the entry door at least 32 inches wide? Is there a larger stall or an area in the restroom at least 36 inches in...
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal. Unisex...