A. Yes. Under Requirement 4, there must be an accessible route into and through the dwelling unit. This would preclude a split level foyer, unless a properly sloped ramp can be...
Search Results "Lavatory Clear Floor Space"
-
21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
-
4.2 Applications of Findings in Design and Standards Development
However, there are some cases in which the implications are much broader, for example, length of clear floor area, knee and toe space clearances, 360-degree turning space, and front reach...
- SafePath Courtedge™ Reducer Ramps
-
Video remote interpreting (VRI) services. (Section-by-Section Analysis)
NPRM, the Department proposed the inclusion of four performance standards for VRI (which the NPRM termed video interpreting services (VIS)), for effective communication: (1) High-quality, clear...
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1....
- ADA Now - Online Quarterly Newsletter from the ACTCP
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
Thresholds: ADA Standard Section 608.7
Section 608.7 covers the current ADA Standards for thresholds in shower compartments.
-
11B-608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would disturb the structural reinforcement of the floor...
-
11B-217.4.1 Bank requirement
[2010 ADA Standards] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
Dispensers: ADA Standard Section 604.9.6
Section 604.9.5 covers the current ADA Standards for dispensers in children's use toilet compartments.
-
11B-608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would disturb the structural reinforcement of the floor...
-
11B-217.4.1 Bank requirement
[2010 ADA Standards] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
Bathtub Seats: ADA Standard Section 610.2
Section 610.2 covers the current ADA Standards for bathtub seats.
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
4(5)
(5) Exterior deck, patio, or balcony surfaces are no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed of impervious material such...
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
Radiologic Equipment
Adequate floor space to maneuver and position stretcher. 3. Stretcher locked in place to prevent movement during lateral transfer. 4....
-
III-4.1400 Surcharges
ILLUSTRATION: The ABC pharmacy is located on the second floor of an older four-story building that does not have an elevator....