Door secured with tumbler lock. Bradley liquid soap valves operate best with any vegetable oil or coconut oil hand soap having a 10−15% soap concentration....
Search Results "Door Surface"
- Bradley Contemporary Series Recess Mounted Soap Dispenser 6437
- GE® 24" Standard Clean Free-Standing Electric Range JAS02SNSS
- AJW Architectural Products U580 1.5 Gallon Sanitary Napkin Disposal - Partition Mounted
- Bradley 2.8 Gallon Waste Receptacle
- Trench Drain SSB 5038TR .75 Base
-
Executive Summary
We also measured performance during door use tasks via the use of observational rating scales....
- Bradley Round Corners Medium, Capacity Towel Dispenser / 12 Gallon Waste 234
- ElectionSource EZ VOTE Wheelchair Accesible Voting Booth
-
Voting Area
If voters are expected to vote at counters or tables, there should be a writing surface that provides knee and toe clearance so that a voter who uses a wheelchair may sit at and use the...
-
Refreshment Table
Avoid billowing or long tablecloths that pool on the floor -- wheelchair wheels and tips of canes, crutches, and walkers can easily catch on flowing linens and pull them off surfaces....
-
11B-308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
Issue 9: Reach (how far?)
The APS shown in Figure 13 are appropriately located within the landscape strip, reachable from a paved level surface, and aligned with the crosswalk lines....
-
Q3.) What are the types of “manufacturing processes” that were anticipated where the advisory says “tolerances recognized by this provision include… “those that may be a necessary consequence of a particular manufacturing process”?
Similarly, the surfaces of ceramic tiles that form the wall behind a grab bar will not be perfectly flat due the manufacturing processes that make them. ...
-
Seats
The deck surface between the centerline of the seat and the pool edge cannot have a slope greater than 1:48....
-
R105 Definitions (Section-by-Section Analysis)
ramp, element, facility, grade break, operable part, pedestrian access route, pedestrian circulation path, public right-of-way, qualified historic facility, running slope, and vertical surface...
-
Supporting Documents for the Medical Diagnostic Equipment Accessibility Standards Advisory Committee Report
Chairs Subcommittee Report - Imaging Equipment Subcommittee Report - Mammography Subcommittee Report - Stretchers Subcommittee Report - Weight Scales IDeA Center Memo – Transfer Surface...
-
FEATURES
Beds, stretchers, and other types of equipment will have unique features that determine the shapes of their patient support surfaces....
-
1009.4.5 Grab Bars
The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls....
-
11B-1009.4.5 Grab bars
The top of the gripping surface shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above transfer walls....
-
Edge Protection
Recommendation: At narrow routes in particular, consider maintenance of adjacent surfaces as raised or flush or wider route widths in consideration of minimum maneuvering and passage requirements...
-
Temporary Suspension
reflecting pools [4.29.6] Detectable warnings are not prohibited by this suspension; jurisdictions may continue to install the truncated domes specified in ADAAG or other surfaces...
-
Landings [4.8.4]
It is recommended that landings of exterior ramps be drained so that water does not accumulate on the surface....
-
C. Defendants' Transaction Counter
But “[b]ecause of the cash registers and merchandise displays . . . defendant does not provide a 36-inch-long clear counter surface.” Id....