Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
Search Results "Access Aisle Width"
Commonly Searched Documents
-
11B-407.4.1 Car dimensions
-
11B-407.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
-
Introduction
The ADA requires that new construction and alterations to existing facilities comply with the ADA Standards for Accessible Design 1 (Standards)....
-
Birthing Room Bath Tub Accessibility
I was surprised to find that the highlighted selection supports the Owner's desire not to provide a seat or grab bars to the bathtub in a birthing room that has an accessible shower....
-
Are accessible parking spaces required on a site where valet service is provided but vehicles are parked off site, such as in a public parking garage or on public streets?
Parking facilities with valet parking must provide accessible parking spaces to allow self-parking by people with disabilities (and must also provide an accessible passenger loading zone...
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
Rationale for the recommendation The recommendation for stretchers is for a smaller clearance width than the 44-inch minimum for other equipment....
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
“Priority” Seating Method
The fourth “priority” bulkhead seat has been assigned to a passenger who also checked in two hours before the flight and uses an aisle chair to enplane who prefers the bulkhead seat to a...
-
May I ask an individual what his or her disability is?
You may ask, “Are you able to transfer from the aisle chair over a fixed aisle seat armrest?” You may ask, “Can you walk from this gate to your connecting gate?”...
- Whitehall Mfg. WH2125A On-Floor Bariatric Stainless Steel Toilet
-
Dispersion
Accessible seating should be located to maximize flexibility in multi-purpose facilities....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
§ 38.79(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
§ 38.117(b)
(b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
§ 38.99(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
G.7.ii. - Are there any circumstances under which Federal EIT must be retrofitted with EIT that meets the access board's standards?
Section 508(a) generally requires that agencies ensure that the EIT they develop, procure, maintain, or use meets the Access Board's standards....
-
Sales Counters
Exception 2 acknowledges that check writing surfaces are a type of work surface and that those provided at inaccessible check-out aisles are not required to comply....
-
11B-206.4.10 Medical care and long-term care facilities
The area of weather protection shall include the passenger loading zone complying with Section 11B-209.3 and the accessible route from the passenger loading zone to the accessible entrance...