Rear-facing wheelchair securement systems shall provide forward excursion barriers and padded head rests that comply with ISO 10865-1:2012(E), Wheelchair containment and occupant retention...
Search Results "Wheelchair Space (Assembly)"
-
T603.5 Securement Systems for Rear-Facing Wheelchair Positions
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
221 Assembly Areas
[See subsections ...]
-
A4.33 Assembly Areas
[See subsections ...]
-
4.33 Assembly Areas
[See subsections ...]
-
4.33 ASSEMBLY AREAS
[See subsections ...]
-
A4.33 ASSEMBLY AREAS
[See subsections ...]
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum....
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
These dimensions are: (A) occupied width, the horizontal distance between the side-most (lateral-most) points of the wheelchair or occupant on the right and left side; (B) occupied length...
-
Wheelchair Space or Transfer Seat or Transfer Device
Wheelchair Space or Transfer Seat or Transfer Device....
- Access Board: Passing Spaces
-
T602 Wheelchair Spaces
[See subsections ...]
-
Best Practice Recommendations for Layout Planning
If 10% or more of participants are expected to use mobility aids, plan for 30% additional space....
-
F206.2.4 Spaces and Elements
In assembly areas with fixed seating required to comply with F221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an accessible...
-
206.2.4 Spaces and Elements
In assembly areas with fixed seating required to comply with 221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an accessible...
-
Clear Floor or Ground Space: ADA Standard Section 811.2
A clear floor or ground space complying with 305 shall be provided....
-
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
-
§ 35.138 Ticketing
§ 35.138 Ticketing.
-
Width [4.3.3.] and Passing Space [4.3.4]
However, the minimum width of hallways and corridors is often further determined by ADAAG requirements for clear floor space at elements such as drinking fountains, door maneuvering clearances...
-
Space
A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby....