If lifts, ramps or bridge plates meeting the requirements of this section are provided on station platforms or other stops required to be accessible, or mini-high platforms complying with...
Search Results "Push Plate"
-
§ 38.83(a)(2) Exception
- AJW Architectural Products U711 Series 16"W x 20"H Channel Frame Mirror - Plate Glass Surface
-
Restrooms Main Lobby
The force required to push or pull open the interior hinged doors to the restroom vestibule door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
- AJW Architectural Products U700 Series 16"W x 20"H Angle Frame Mirror - Plate Glass Surface
-
1008.1.9.7, Item 5
A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING....
-
Handrail Extensions
Handrail extensions are not required where gangways and transition plates connect and both are provided with handrails....
-
11B-411.2.3.2 Car designation signs
Applied plates are acceptable if they are permanently fixed to the jamb....
- Doorbell Factory Medium Rectangle Stainless Steel Doorbell
- Morgan’s Inspiration Island - San Antonio, Texas
-
A4.13.9 DOOR HARDWARE
Some disabled persons must push against a door with their chair or walker to open it....
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
-
1133A.6 Kitchen sink faucet controls
Lever-operated, push-type and electronically controlled mechanisms are examples of acceptable designs....
-
1133A.6 Kitchen sink faucet controls
Lever-operated, push-type and electronically controlled mechanisms are examples of acceptable designs....
- SmartWheel Manual Wheelchair Evaluation Tool
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
11B-404.2.4.1 Swinging doors and gates
unless noted) From front Pull 60 inches (1524 mm) 18 inches (457 mm)5 From front Push...
-
A4.13.9 Door Hardware
Some disabled persons must push against a door with their chair or walker to open it....
-
Inventory Control Devices
A minimum 12 inch clearance is required on the push side of swinging doors when the door has both a closer and a latch....
-
§ 38.83(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas...
-
Toilet Rooms-Banquet Area
The force required to push or pull open the doors to the women's and men's toilet rooms designated as accessible is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
Maneuvering Clearances at Doors [4.13.6]
Latch-side clearance is needed on the push side to be able to operate a latch and maneuver through the door against the force of a closer....