Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
Search Results "Out-Swinging Door"
-
11B-404.2 Manual doors, doorways, and manual gates
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with 227 and 904....
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-809.1.1 Door signal devices
In buildings with three or more residential dwelling units, the primary entry door to the dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
B. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the restroom door from the pull side and pull it open without it hitting the wheelchair - this requires at least 18"...
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
B. Door Clear Width
Does at least one lobby entrance door allow at least 32" clear passage width so persons who use wheelchairs, walkers, crutches, and other mobility aids can get through the door?...
-
904 Sales and Service Counters
This section covers the approach to counters (904.2), check-out aisles (904.3), sales and service counters (904.4), food service lines (904.5), and security glazing (904.6)....
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
11. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the bathroom door in each accessible guestroom bathroom from the pull side and pull it open without it hitting the wheelchair...
-
4.13 Doors
[See subsections ...]
-
A4.13 Doors
[See subsections ...]
-
A4.13 DOORS
[See subsections ...]
-
4.13 DOORS
[See subsections ...]
-
Are exit doors usable only in one direction required to comply on both sides?
Under the ADA Standards, compliance is not required on both sides of those doors or gates that can be used in one direction only, such as exit-only doors....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....