404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
Search Results "Out-Swinging Door"
-
404.2 Manual Doors, Doorways, and Manual Gates
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
Shower and Sauna Doors in Transient Lodging Facilities
Shower and Sauna Doors in Transient Lodging Facilities....
-
224.1.2 Guest Room Doors and Doorways
224.1.2 Guest Room Doors and Doorways....
-
Toilet Compartment Access
If the door and access were from the opposite side, although not as accessible I believe it is also §404 compliant because a self-closing door is not the same as a door with a closer? ...
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
1132A.3, Item 3
Swinging doors shall be capable of opening at least 90 degrees....
-
1132A.3, Item 3
Swinging doors shall be capable of opening at least 90 degrees....
-
F224.1.2 Guest Room Doors and Doorways
Advisory F224.1.2 Guest Room Doors and Doorways....
-
224.1.2 Guest Room Doors and Doorways
Advisory 224.1.2 Guest Room Doors and Doorways....
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
Maneuvering Space at Doors
Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard....
-
11B-904.3.4 Identification sign
When not all check-out aisles are accessible, accessible check-out aisles shall be identified by a sign clearly visible to a person in a wheelchair displaying the International Symbol of...
-
11B-904.3.4 Identification sign
When not all check-out aisles are accessible, accessible check-out aisles shall be identified by a sign clearly visible to a person in a wheelchair displaying the International Symbol of...
-
11B-904.3.4 Identification sign
When not all check-out aisles are accessible, accessible check-out aisles shall be identified by a sign clearly visible to a person in a wheelchair displaying the International Symbol of...
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
904.3.1 Aisle
Aisles shall comply with 403.
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.