Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
Search Results "Maximum Dimension"
-
11B-302.3 Openings
-
Perpendicular Curb Ramps (R304.2) (Section-by-Section Analysis)
Where the turning space is constrained at the back of the sidewalk, the turning space must be 1.2 meters (4 feet) minimum by 1.5 meters (5 feet) minimum, with the 1.5 meters (5 feet) dimension...
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
Comments should include information on sources to support the dimensions, where possible....
-
R103.1 Conventional Industry Tolerances
Dimensions are subject to conventional industry tolerances except where dimensions are stated as a range. Advisory R103.1 Conventional Industry Tolerances....
-
405 Ramps
A 1:10 maximum slope is permitted for ramps with a rise of up to 6 inches, and a maximum 1:8 slope is allowed for ramps with a rise of up to 3 inches. Comment....
-
e-ii
[ADA Standards § 4.10.9, Fig. 22] Yes No Note: See Figure 22 for acceptable floor and opening dimensions....
-
4.1.6(3)(c)(iii)
(iii) Equivalent facilitation may be provided with an elevator car of different dimensions when usability can be demonstrated and when all other elements required to be accessible comply...
-
5b.
[ADA Stds 4.10.9] Note: See Figure 22 for acceptable floor and opening dimensions....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
The 30-inch dimension is based on the width of a stationary occupied wheelchair....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of manual chair (n=276), power chair (n=189), and scooter (n=30) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
The accompanying table provides dimensions values for clear floor area to accommodate 95% of scooter (n=30), power chair (n=189), and manual chair (n=276) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of power chair (n=189), scooter (n=30), and manual chair (n=276), users that were measured as part...
-
Transfer Sides (M301.2.3 and M302.2.3)
Patients who use mobility devices would have the choice to approach parallel to the deep dimension of the transfer surface, parallel to the wide dimension of the transfer surface, or at...
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Wall furr-out to support a grab bar when toilet is too far from the side wall
It's like what Daniel is describing but I'm not sure about the exact dimensions or construction details of the one in these photos....
-
§ 36.311(b)(2)(i)
(i) The type, size, weight, dimensions, and speed of the device;...
-
§ 35.137(b)(2)(i)
(i) The type, size, weight, dimensions, and speed of the device;...
-
Transfer Surface Size: Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301.2.2)
The transfer surface dimensions do not include headrests, footrests, or similar supports for body extremities that do not support the patient’s overall body position....
-
407.4.6.2.1 Size
Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....