11B-608.2.1 Transfer type shower compartments
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
DETR
A checkerboard was mounted behind the stand from which dimensions could be scaled from photographs....
-
Summary
Summary The following report provides a brief analysis of four anthropometric dimensions which were considered relevant to the width and depth dimensions of a seating surface for wheeled...
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
- Inpro Corporation ENDURANT® Trench Drain Receptor
-
11B-703.6.1 Pictogram field
The 6-inch vertical dimension applies to the field, not the symbol. The symbol may be smaller than the field....
-
11B-703.6.1 Pictogram field
The 6-inch vertical dimension applies to the field, not the symbol. The symbol may be smaller than the field....
-
Do the surface requirements, including those for maximum slope (1:48), apply to all portions of a parking lot?
No, the surface criteria apply only to accessible parking spaces, access aisles, and accessible routes, including those serving other elements or spaces besides parking spaces....
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
Perpendicular Curb Ramps (R304.2) (Section-by-Section Analysis)
Where the turning space is constrained at the back of the sidewalk, the turning space must be 1.2 meters (4 feet) minimum by 1.5 meters (5 feet) minimum, with the 1.5 meters (5 feet) dimension...
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
Comments should include information on sources to support the dimensions, where possible....
-
R103.1 Conventional Industry Tolerances
Dimensions are subject to conventional industry tolerances except where dimensions are stated as a range. Advisory R103.1 Conventional Industry Tolerances....
-
405 Ramps
A 1:10 maximum slope is permitted for ramps with a rise of up to 6 inches, and a maximum 1:8 slope is allowed for ramps with a rise of up to 3 inches. Comment....
-
e-ii
[ADA Standards § 4.10.9, Fig. 22] Yes No Note: See Figure 22 for acceptable floor and opening dimensions....
-
4.1.6(3)(c)(iii)
(iii) Equivalent facilitation may be provided with an elevator car of different dimensions when usability can be demonstrated and when all other elements required to be accessible comply...
-
5b.
[ADA Stds 4.10.9] Note: See Figure 22 for acceptable floor and opening dimensions....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
The 30-inch dimension is based on the width of a stationary occupied wheelchair....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair